<title>Effects of Fire Hazards Due to Leakage in Gas Circulation Lines in Bangladesh</title>
<link href="http://220.247.167.101:8080/xmlui/handle/123456789/41" rel="alternate"/>
<author>
<name>Abdullah, Md</name>
</author>
<author>
<name>Abedin, Mohammad Zoynal</name>
</author>
<author>
<name>Hossen, Saddam</name>
</author>
<id>http://220.247.167.101:8080/xmlui/handle/123456789/41</id>
<updated>2023-09-24T08:30:22Z</updated>
<published>2022-01-01T00:00:00Z</published>
<summary type="text">Effects of Fire Hazards Due to Leakage in Gas Circulation Lines in Bangladesh
Abdullah, Md; Abedin, Mohammad Zoynal; Hossen, Saddam
Fire hazards caused by leakages in gas circulation lines are dangerous and pose a threat that results in a significant loss&#13;
of wealth, lives, and the environment. By adopting significant precautions, the risks of fire hazards can be reduced&#13;
effectively through the use of new technologies and preventive measurements of the system. In addition, the effects&#13;
of fire hazards due to leakage in gas circulation lines in the buildings as well as in the other systems can be assessed&#13;
to create the context of preventive measures for a fire protection system in a way to overcome the fire hazards in&#13;
gas circulation lines. The paper aims to review the effects of fire hazards due to leakage in gas circulation lines in&#13;
Bangladesh. It is noted that in Bangladesh during 2018-2019, the total gas distribution line in the Titas gas system was&#13;
measured as 13,138 km where the pressure-reducing system or gas riser was found as 1.2 million and the number of&#13;
customers was found as 2.866 million. In the system, the number of fire accidents that occurred was 208 in the&#13;
circulation system. Because of connecting the illegal gas lines and poor maintenance of the system, Bangladesh faces&#13;
significant fire hazards every year. To avoid this kind of problem, proper maintenance along with the varieties of&#13;
new technologies incorporating sensors and microcontrollers can be utilized.
</summary>
<dc:date>2022-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>DEVELOPMENT AND PERFORMANCE OPTIMIZATION OF VERTICAL AXIS WIND TURBINE USING AVP</title>
<link href="http://220.247.167.101:8080/xmlui/handle/123456789/37" rel="alternate"/>
<author>
<name>Alam, Md. Mahmodul</name>
</author>
<author>
<name>Ahmed, Irfan</name>
</author>
<author>
<name>Joy, Md. Golam Rasul</name>
</author>
<author>
<name>Kamal, Maksud</name>
</author>
<author>
<name>Anim, Md. Tahmid</name>
</author>
<author>
<name>Islam, Tanjila</name>
</author>
<author>
<name>Amin, Iftekhar</name>
</author>
<id>http://220.247.167.101:8080/xmlui/handle/123456789/37</id>
<updated>2023-09-24T04:58:56Z</updated>
<published>2021-01-01T00:00:00Z</published>
<summary type="text">DEVELOPMENT AND PERFORMANCE OPTIMIZATION OF VERTICAL AXIS WIND TURBINE USING AVP
Alam, Md. Mahmodul; Ahmed, Irfan; Joy, Md. Golam Rasul; Kamal, Maksud; Anim, Md. Tahmid; Islam, Tanjila; Amin, Iftekhar
This investigation focuses on the development and performance optimization of Vertical Axis&#13;
Wind Turbine (VAWT) by using Asymmetric Vortex Provider (AVP). This experiment has been carried out&#13;
at BAUST campus, Saidpur where the local velocity is much lower than the coastal areas. The objective&#13;
was to build a VAWT with a very low starting speed as well as performance optimization which have been&#13;
accomplished by using 6 blade section AVP made of PVC. This study shows that after using AVP, this VAWT&#13;
is capable of producing power at very low wind speed under different conditions. It also depicts that using&#13;
AVP doesn’t increase the moment of inertia whereas it increases the RPM tremendously at any wind speed&#13;
along with the turbine efficiency. The RPM was measured and compared at different conditions and it shows&#13;
that at the same wind speed, the rpm of VAWT with AVP is much higher than the rpm of VAWT without AVP.&#13;
The local velocity of the turbine is also increased by using AVP. This whole investigation suggests that, AVP&#13;
can be a solution for those areas where wind speed is not enough to rotate the turbine blade to produce&#13;
electric power.
</summary>
<dc:date>2021-01-01T00:00:00Z</dc:date>